Sloan Royal® Closet Flushometer - 1.28GPF
Sloan Royal® Closet Flushometer.
• Adjustable tailpiece
• Free spinning vandal resistant stop cap
• 1” IPS screwdriver Bak-Chek® angle stop
• CID™ technology controlled flush accuracy
• Spud coupling and flange for 1-1/2” top spud
• Permex™ rubber diaphragm with dual filtered bypass
• High copper, low zinc brass castings for dezincification resistance
• Sweat solder adapter with cover tube and cast wall flange with set screws
• High back pressure vacuum breaker flush connection with one-piece bottom hex coupling nut
• ADA compliant metal oscillating non-hold-open handle with triple seal
• Diaphragm, handle packing, stop seal and vacuum breaker molded from Permex™ rubber compound for chloramine resistance
• Non-hold-open handle, fixed metering bypass and no external volume adjustment to ensure water conservation
NOTE: Valve body, cover, tailpiece and control stop shall be in conformance with ASTM Alloy Classification for semi-red brass, Valve shall be in compliance to the applicable sections of ASSE 1037
• For California Residents please see Prop 65 Warnings
• Adjustable tailpiece
• Free spinning vandal resistant stop cap
• 1” IPS screwdriver Bak-Chek® angle stop
• CID™ technology controlled flush accuracy
• Spud coupling and flange for 1-1/2” top spud
• Permex™ rubber diaphragm with dual filtered bypass
• High copper, low zinc brass castings for dezincification resistance
• Sweat solder adapter with cover tube and cast wall flange with set screws
• High back pressure vacuum breaker flush connection with one-piece bottom hex coupling nut
• ADA compliant metal oscillating non-hold-open handle with triple seal
• Diaphragm, handle packing, stop seal and vacuum breaker molded from Permex™ rubber compound for chloramine resistance
• Non-hold-open handle, fixed metering bypass and no external volume adjustment to ensure water conservation
NOTE: Valve body, cover, tailpiece and control stop shall be in conformance with ASTM Alloy Classification for semi-red brass, Valve shall be in compliance to the applicable sections of ASSE 1037
• For California Residents please see Prop 65 Warnings
Manufacture Item Number | 3910168 |
UPC | 671254209794 |
Weight | 6.9 |
Package Quantity | EACH |
GPF / LPF | 1.28/4.8 |
Model | 111-1.28 |
Details
Sloan Royal® Closet Flushometer.
• Adjustable tailpiece
• Free spinning vandal resistant stop cap
• 1” IPS screwdriver Bak-Chek® angle stop
• CID™ technology controlled flush accuracy
• Spud coupling and flange for 1-1/2” top spud
• Permex™ rubber diaphragm with dual filtered bypass
• High copper, low zinc brass castings for dezincification resistance
• Sweat solder adapter with cover tube and cast wall flange with set screws
• High back pressure vacuum breaker flush connection with one-piece bottom hex coupling nut
• ADA compliant metal oscillating non-hold-open handle with triple seal
• Diaphragm, handle packing, stop seal and vacuum breaker molded from Permex™ rubber compound for chloramine resistance
• Non-hold-open handle, fixed metering bypass and no external volume adjustment to ensure water conservation
NOTE: Valve body, cover, tailpiece and control stop shall be in conformance with ASTM Alloy Classification for semi-red brass, Valve shall be in compliance to the applicable sections of ASSE 1037
• For California Residents please see Prop 65 Warnings
• Adjustable tailpiece
• Free spinning vandal resistant stop cap
• 1” IPS screwdriver Bak-Chek® angle stop
• CID™ technology controlled flush accuracy
• Spud coupling and flange for 1-1/2” top spud
• Permex™ rubber diaphragm with dual filtered bypass
• High copper, low zinc brass castings for dezincification resistance
• Sweat solder adapter with cover tube and cast wall flange with set screws
• High back pressure vacuum breaker flush connection with one-piece bottom hex coupling nut
• ADA compliant metal oscillating non-hold-open handle with triple seal
• Diaphragm, handle packing, stop seal and vacuum breaker molded from Permex™ rubber compound for chloramine resistance
• Non-hold-open handle, fixed metering bypass and no external volume adjustment to ensure water conservation
NOTE: Valve body, cover, tailpiece and control stop shall be in conformance with ASTM Alloy Classification for semi-red brass, Valve shall be in compliance to the applicable sections of ASSE 1037
• For California Residents please see Prop 65 Warnings