Taco 00 Series Single Phase Circulating Pump - 1/8 H.P., 115V, 1.1 Amp, 60 Hz, 3250 RPM
Taco “00” cartridge circulator is designed to make your job easier. Installation is quick and easy, and maintenance is a snap. With no mechanical seal, the self-lubricating design provides unmatched reliability. Every “00” features a field-replaceable cartridge that contains all the moving parts. Cast Iron Taco 0010-F3-1IFC Circulator Pump with an Integral Flow Check (IFC) is designed to reduce installation costs when using Taco 0010 circulators. The bulit-in IFC increases the flow performance when compared to regular in-line check valve. Taco 0010-F3-1IFC model can be used for medium head, medium/higher flow residential or light commercial applications such as hydronic heating, radiant floor heating, and hydro-air fan coils. Both the IFC (Integral Flow Check) and circulator pump cartridge are easily accessed for service and eliminate the need for replacing the entire unit.• Integral Flow check (IFC) Patent #5,664,939.
• Prevents gravity flow.
• Eliminates separate in-line flow check.
• Reduces installed cost, easy to service.
• Improved performance compared to in-line flow checks.
• Unique replaceable cartridge.
• Field serviceable.
• Unmatched reliability.
• Maintenance free.
• Quiet and efficient operation.
• Direct drive.
• Low power consumption.
• Self lubricating.
• No mechanical seal.
• Standard high capacity output.
• Compact design.
• Wide range of applications
• Flanged connections.
• Cast iron.
• Less flanges.
• 115 Volt, 60 Hz, 3250 RPM.
• Standard high capacity output.
• Direct drive, low power consumption.
• Universal flange to flange dimension.
Applications:
• Hydronic heating/cooling.
• Radiant heating.
• Zoning with pumps.
• Hydro-Air fan coils.
Replacement Parts List:
• Casing O-Ring: 0010-008RP
• Flange Gasket Set: 007-007RP
• Capacitor or PC Board: 009-018RP
• Cartridge Assembly Complete: 0010-021RP
• Valve Addembly Trans/Relay: 0012-021RP
• For California Residents please see Prop 65 Warnings
• Prevents gravity flow.
• Eliminates separate in-line flow check.
• Reduces installed cost, easy to service.
• Improved performance compared to in-line flow checks.
• Unique replaceable cartridge.
• Field serviceable.
• Unmatched reliability.
• Maintenance free.
• Quiet and efficient operation.
• Direct drive.
• Low power consumption.
• Self lubricating.
• No mechanical seal.
• Standard high capacity output.
• Compact design.
• Wide range of applications
• Flanged connections.
• Cast iron.
• Less flanges.
• 115 Volt, 60 Hz, 3250 RPM.
• Standard high capacity output.
• Direct drive, low power consumption.
• Universal flange to flange dimension.
Applications:
• Hydronic heating/cooling.
• Radiant heating.
• Zoning with pumps.
• Hydro-Air fan coils.
Replacement Parts List:
• Casing O-Ring: 0010-008RP
• Flange Gasket Set: 007-007RP
• Capacitor or PC Board: 009-018RP
• Cartridge Assembly Complete: 0010-021RP
• Valve Addembly Trans/Relay: 0012-021RP
• For California Residents please see Prop 65 Warnings
Manufacture Item Number | 0010-F3 |
UPC | 687752246988 |
Weight | 10.85 |
Package Quantity | EACH |
A (in) | 7-1/4 |
B (in) | 5-11/16 |
C (in) | 3-3/16 |
D (in) | 3-5/16 |
F (in) | 5-3/8 |
G (in) | 6-3/8 |
Amp | 1.1 |
H.P. | 1/8 |
Weight (lbs) | 13 |
Details
Taco “00” cartridge circulator is designed to make your job easier. Installation is quick and easy, and maintenance is a snap. With no mechanical seal, the self-lubricating design provides unmatched reliability. Every “00” features a field-replaceable cartridge that contains all the moving parts. Cast Iron Taco 0010-F3-1IFC Circulator Pump with an Integral Flow Check (IFC) is designed to reduce installation costs when using Taco 0010 circulators. The bulit-in IFC increases the flow performance when compared to regular in-line check valve. Taco 0010-F3-1IFC model can be used for medium head, medium/higher flow residential or light commercial applications such as hydronic heating, radiant floor heating, and hydro-air fan coils. Both the IFC (Integral Flow Check) and circulator pump cartridge are easily accessed for service and eliminate the need for replacing the entire unit.• Integral Flow check (IFC) Patent #5,664,939.
• Prevents gravity flow.
• Eliminates separate in-line flow check.
• Reduces installed cost, easy to service.
• Improved performance compared to in-line flow checks.
• Unique replaceable cartridge.
• Field serviceable.
• Unmatched reliability.
• Maintenance free.
• Quiet and efficient operation.
• Direct drive.
• Low power consumption.
• Self lubricating.
• No mechanical seal.
• Standard high capacity output.
• Compact design.
• Wide range of applications
• Flanged connections.
• Cast iron.
• Less flanges.
• 115 Volt, 60 Hz, 3250 RPM.
• Standard high capacity output.
• Direct drive, low power consumption.
• Universal flange to flange dimension.
Applications:
• Hydronic heating/cooling.
• Radiant heating.
• Zoning with pumps.
• Hydro-Air fan coils.
Replacement Parts List:
• Casing O-Ring: 0010-008RP
• Flange Gasket Set: 007-007RP
• Capacitor or PC Board: 009-018RP
• Cartridge Assembly Complete: 0010-021RP
• Valve Addembly Trans/Relay: 0012-021RP
• For California Residents please see Prop 65 Warnings
• Prevents gravity flow.
• Eliminates separate in-line flow check.
• Reduces installed cost, easy to service.
• Improved performance compared to in-line flow checks.
• Unique replaceable cartridge.
• Field serviceable.
• Unmatched reliability.
• Maintenance free.
• Quiet and efficient operation.
• Direct drive.
• Low power consumption.
• Self lubricating.
• No mechanical seal.
• Standard high capacity output.
• Compact design.
• Wide range of applications
• Flanged connections.
• Cast iron.
• Less flanges.
• 115 Volt, 60 Hz, 3250 RPM.
• Standard high capacity output.
• Direct drive, low power consumption.
• Universal flange to flange dimension.
Applications:
• Hydronic heating/cooling.
• Radiant heating.
• Zoning with pumps.
• Hydro-Air fan coils.
Replacement Parts List:
• Casing O-Ring: 0010-008RP
• Flange Gasket Set: 007-007RP
• Capacitor or PC Board: 009-018RP
• Cartridge Assembly Complete: 0010-021RP
• Valve Addembly Trans/Relay: 0012-021RP
• For California Residents please see Prop 65 Warnings